Compare Three Model-Scoped Prefabricated Substation Examples
Select at least two columns to compare values found in three Talite product documents. This tool shows documented examples, not the company’s complete range and not a substitute for a project quotation.
Choose comparison columns
| Decision field | High and Low Voltage Prefabricated Substation | Outdoor Prefabricated Compact Substation | European Substation Power Transformer |
|---|---|---|---|
| Capacity | 1600 kVA | 3000 kVA | 2000 kVA |
| Voltage shown | 11 / 12 / 13.8 kV | 24.94 / 12.47 kV | 11 kV |
| Confirmed arrangement | HV equipment, power transformer, and LV equipment integrated in one enclosure | Outdoor integrated distribution and control arrangement | Integrated compact and movable format |
| Documented context | Factory-prefabricated delivery concept | Ring-network or terminal distribution; urban grid and industrial park | Public distribution, commercial, industrial park, or residential |
| Still required from buyer | Frequency, fault level, protection, site, standard, and interfaces | Network role, protection, outdoor conditions, site, standard, and interfaces | Load, network, access, site, standard, and delivery scope |
Use the examples as evidence, not a selector
Start with the electrical role of the planned substation. Read each visible column as one documented configuration. Treat a listed capacity as model-scoped data. Keep its voltage beside it. Record unknown fields in the RFQ. Use the model name when discussing the example. Confirm fit against the project’s own inputs. Send the final basis for engineering review.
Interpret the comparison carefully
Capacity and voltage alone do not establish fit. Protection, switchgear, insulation, fault level, environmental duty, access, applicable standards, tests, documents, and delivery responsibilities can change the actual configuration. A visible match in this table therefore identifies a discussion starting point; it does not confirm that the transformer, enclosure, HV/LV lineup, relay scheme, internal connection, transport split, installation boundary, or authority path is suitable for a different project. Engineering review remains required.
Data boundary: every numeric value is tied to one reviewed Talite document. No “up to” rating, price, lead time, certification, or complete product range is inferred.